A range hood consumes electricity via the fan, lighting, and standby load. To estimate annual cost, calculate each channel independently and sum them. The fan is usually the largest variable, but lighting can overtake it if left on for hours. Standby load adds a fixed baseline.
Fan Wattage by Hood Type and Speed Setting
Under-cabinet and slide-out ducted hoods draw 65-150 W. Wall-mount chimney and insert hoods draw 150-300 W. Island and professional-style high-CFM models draw 300-700 W. Recirculating ductless hoods draw 100-250 W as the charcoal filter restricts airflow. The highest speed can draw roughly three times the lowest: 60-80 W on low, 120-180 W on medium, and 200-300 W on high for a mid-range unit. Running a lower speed longer is usually cheaper (e.g., 200 W for 30 mins = 0.1 kWh; 70 W for 60 mins = 0.07 kWh, a 30% reduction). Longer duct runs with bends increase static pressure and fan wattage.
Annual Fan kWh and Cost Calculation
Formula: fan wattage × daily runtime hours × 365 / 1000. A 150 W fan run 1 hour/day = 54.75 kWh/year, costing $8.21 at $0.15/kWh. An ENERGY STAR 75 W model uses 27.375 kWh ($4.11). At 1.5 hours daily (150 W), it’s 82.125 kWh ($12.32). At 20 minutes daily, it’s 18.25 kWh ($2.74). Note that the hood also exhausts conditioned air, creating extra heating/cooling costs.
Lighting Wattage and Annual Contribution
Older hoods often use two 50 W halogen bulbs (100 W total), which can exceed fan wattage on low speed. Modern LED equivalents use 5-7 W total, reducing energy by 93%. Formula: total lighting wattage × daily hours on × 365 / 1000. Two 50 W halogens on 3 hours daily = 109.5 kWh ($16.43). Two 6 W LEDs = 6.57 kWh ($0.99). Bulb choice can change annual cost by over $15.
Standby Power and Phantom Load
Hoods with digital features draw 1-2 W continuously. A 1.5 W load consumes 13.14 kWh/year ($1.97); a 0.5 W load consumes 4.38 kWh ($0.66). Delayed shutoff timers (5-15 mins) add runtime: 150 W for 10 mins daily = 9.14 kWh/year ($1.37).
Ducted vs Recirculating Hoods and Motor Efficiency
Ducted hoods require less wattage per CFM. Recirculating hoods face charcoal filter resistance, drawing 25-60% more wattage (e.g., 150 W ductless vs 100 W ducted for same CFM, costing 50% more). DC motors use up to 70% less electricity than AC motors (e.g., 75 W DC vs 200 W AC). Compare rated wattage at each speed, not just CFM.
Combined Annual Cost and Realistic Runtime Scenarios
Sum fan, lighting, and standby components. 1) Under-cabinet: 100 W fan (1 hr), 12 W LEDs (2 hrs), 1 W standby. Fan=36.5, light=8.76, standby=8.76 kWh. Total=54.02 kWh ($8.10). 2) Wall-mount: 250 W fan (1.5 hrs), 100 W halogens (4 hrs), 1.5 W standby. Fan=136.875, light=146, standby=13.14 kWh. Total=296.015 kWh ($44.40). 3) Island/pro: 500 W fan (1 hr), 12 W LEDs (1 hr), 2 W standby. Fan=182.5, light=4.38, standby=17.52 kWh. Total=204.4 kWh ($30.66).
Seasonal Effects: Conditioned Air Loss
Ducted hoods exhaust conditioned air. A 150 W fan moving 300 CFM exhausts 18,000 cubic feet per hour. Reconditioning this air can cost 2-5 times the fan's electrical draw, depending on climate. Recirculating hoods avoid this indirect cost. Reducing runtime in extreme weather can lower total household energy spending.
Checklist for Estimating Your Range Hood Annual Cost
Identify fan wattage (estimate low at 30-40%, medium at 60-70% of max). Record daily fan runtime (including delayed shutoff). Calculate: fan wattage × daily hours × 365 / 1000. Record lighting wattage and hours; calculate similarly. Check standby wattage; multiply by 24 × 365 / 1000. Sum all kWh and multiply by your local electricity rate. Compare with conditioned air loss costs if ducted in an extreme climate.