Holiday string lights consume electricity based on three numbers: the wattage of each strand, the hours they run each night, and the number of nights in the season. A 100-count incandescent mini string draws about 40 W, while a comparable LED string draws 4 to 7 W. That difference of roughly 83 to 90 percent is the largest single factor in the seasonal bill. The remaining factors are the daily runtime and the local electricity rate.

Strand Wattage by Type and Bulb Count

Incandescent mini lights use about 0.4 to 0.5 W per bulb, so a 100-count strand sits near 40 W. A 100-count LED mini strand uses about 0.07 W per bulb, which lands around 4 to 7 W for the whole strand. The per-bulb ratio means an LED display of the same bulb count consumes less than one fifth of the incandescent wattage in most cases.

Larger bulbs show an even wider gap. A 25-bulb C7 incandescent string pulls about 125 W, while the LED equivalent pulls about 5 W. A 25-bulb C9 incandescent string pulls about 175 W, versus 7 W for LED. These strings are often used on rooflines and large outdoor trees, where the wattage difference becomes a matter of circuit capacity as well as cost.

Other common formats follow the same pattern. A 150-count icicle string or a 4 by 6 foot net light set draws about 63 W in incandescent and about 10 W in LED. An 18-foot rope light with 216 bulbs draws about 72 W in incandescent and about 11 W in LED. For any given format, the LED version uses roughly one sixth to one tenth of the incandescent power.

Seasonal kWh Calculation

The energy used by one strand is the wattage divided by 1,000, multiplied by hours per night and nights in the season. For a 100-count incandescent mini strand at 40 W running six hours per night for 31 days, the consumption is 0.040 kW times 6 hours times 31 days, which equals 7.44 kWh. At an 18 cent per kWh rate, that one strand costs about 1.34 dollars for the season.

The same schedule with a 4 W LED strand uses 0.004 kW times 6 hours times 31 days, equal to 0.744 kWh. At the same rate, the seasonal cost is about 0.13 dollars per strand. A household running ten such strands over 45 days at six hours per night would consume 108 kWh with incandescent mini lights and 18.9 kWh with LED equivalents.

For a longer example with ten 40 W strands running six hours per night for 40 days, the total is 10 strands times 0.040 kW times 6 hours times 40 days, equal to 96 kWh. At 15.9 cents per kWh, that display costs about 15.26 dollars for the season. The same display with 5 W LED strands uses 12 kWh and costs about 1.91 dollars.

Rate Structure and Marginal Cost

The simple cost formula uses the average rate per kWh, but many utilities apply tiered rates. The added holiday load can push a household past a usage threshold, meaning the extra kilowatt-hours are billed at a higher marginal rate than the advertised average. A display that seems inexpensive at the baseline rate may cost noticeably more if it moves the household into a higher tier.

Time-of-use rates add another layer. If the lights run in the evening, the rate may be higher than the off-peak rate used for overnight charging or morning laundry. Checking the utility rate schedule for the specific hours of operation gives a more accurate estimate than using a single flat rate.

For a decorated home, the total incandescent load can reach 1,500 to 2,000 W. The same display in LED typically draws 150 to 200 W. At 120 V, a 2,000 W incandescent load draws about 16.7 A, which can approach the limit of a 15 A circuit. An LED display at 200 W draws about 1.7 A, leaving ample headroom on the same circuit.

Runtimes, Timers, and Display Composition

Because watts are watts, a single large motif can dominate the seasonal cost. A 48 W motif running six hours per night for 40 days uses 11.52 kWh, while several 7 W LED strings under the same schedule use far less. Checking the wattage of each element separately prevents the assumption that a small number of decorative items is cheap.

A timer that limits operation to six evening hours instead of all night roughly halves the seasonal consumption. Running lights from dusk to midnight rather than dawn reduces the hours per night from around 12 to 6, cutting both kWh and cost by half. For households that leave lights on until sunrise, a timer is the most direct way to reduce the bill without changing the display.

Season length also matters. A 45-day season consumes 50 percent more energy than a 30-day season at the same nightly runtime. Shorter seasons, or starting the display later in December, reduce the total kWh proportionally.

Full Display Cost Estimation

To estimate the total seasonal cost, list every strand and motif, note the wattage, and multiply by the nightly hours and season length. For a display with multiple types, sum the wattage first, then apply the formula to the total. For example, a display with 12 LED mini strands at 5 W each, 3 LED C9 strands at 7 W each, and one 48 W motif totals 60 W plus 21 W plus 48 W, equal to 129 W. Running 0.129 kW for six hours over 40 days gives 30.96 kWh, which at 17 cents per kWh costs about 5.26 dollars.

The same display with incandescent equivalents would use much more. Twelve 40 W mini strands, three 175 W C9 strands, and a 48 W motif total 480 W plus 525 W plus 48 W, equal to 1,053 W. Over the same schedule, that is 1.053 kW times 6 hours times 40 days, equal to 252.72 kWh, costing about 42.96 dollars at the same rate.

For a full house or roofline display, the LED version often costs 2 to 5 dollars per season, while the incandescent version costs 15 to 50 dollars. The exact figure depends on the number of strands, the nightly runtime, and the local rate.

Practical Checklist for Estimating Holiday Light Cost

Count every strand and motif, and record the wattage from the label or the bulb count. Use 0.4 to 0.5 W per bulb for incandescent mini lights, 0.07 W per bulb for LED mini lights, and the listed wattage for C7, C9, icicle, net, and rope lights.

Decide the nightly runtime and the number of nights. A timer set for six hours is a common baseline, while all-night operation doubles the consumption. Multiply the total wattage by the runtime and season length, then divide by 1,000 to get kWh. Multiply the kWh by the effective rate per kWh, including any tiered or time-of-use adjustments.

Compare the LED and incandescent totals for the same display. The LED version typically uses 83 to 90 percent less energy. Check the circuit load as well, since a large incandescent display may exceed a 15 A breaker while an LED display of the same visual density will not.